| Electronics |
|
| Power
Requirements: |
120/220 VAC,
±15%,50/60 Hz, 12-24 VDC @ 15W max.
|
| Temperature: |
25°F
to 125°F (-5°F with opt. heater) |
| Display: |
2
line x 20 character, Alphanumeric, LCD with LED Backlighting; GPM,
MGD, PERCENT, TOTAL GALLONS |
| Totalizer
(counter) |
One,
8 digit accumulative with programmable multiplier of x1, x10, x100,
x1000. 200 daily, 8 digit totalizers, Data Logging |
|
|
Two
4-20 mA isolated into 1000 ohm max. RS-232 (USB port, MODEM opt.),
5 relay outputs (4 setpoint, 1 programmable Sampler pulse- 250ms
duration) SPDT 5A/250 VAC
|
| Span
Range: |
0-999999.99
GPM full scale |
| Input: |
4-20
mA., any source proportional to level or flow |
| Resolution: |
0.4%
of input |
| Accuracy: |
±1.0%
of input or better |
| Memory: |
Flash
and non-volatile RAM |
| Flow
Equations: |
Programmable
exponent, 0.00 to 9.99; Parshal, Palmer/bowlus, Weirs, Compound Weirs,
20 point lookup table, linear |
| Data
Log: |
200 Day Summary:
avg GPM, time-stamped min/max GPM, and Total Gallons - Programmable
24 hour start-time. Time
Stamped avg GPM with programmable log rate of 00-99 minutes in 1
minute icrements
|
| Download: |
Directly
to serial printer or PC through MODEM. Initiate from PC or from Flowmeter.
Data is preformatted. |
|
|
| Enclosure |
|
| Material: |
Fiberglass
with clear hinged Polycarbonate cover |
| Rating: |
NEMA
4X, IP65, Water-Tight, Dust-Tight and Corrosion-Resistant - CSA, UL
listed |
| Dimensions: |
7.2"
x 11.8" x 6.8" |
| Mounting: |
4.92"
x 12.3" with stainless steel mounting feet |
Options
Heater/Thermostat,
USB port, MODEM ....
Warranty
Systems are pre-tested
and quality control inspected before shipping. Warranty is
against defects in parts and workmanship for a period of one (1) year.
Specifications and design subject to change without notice.
|